beautypg.com

Stats menus – BoonDocker ARCTIC CAT: 700/800 Turbo User Manual

Page 8

background image

BoonDocker – 1585 Hollipark Dr. Idaho Falls, ID 83401 – (208) 542-4411

website: www.boondockers.com - email: [email protected]

Revised 12-01-00

Page 8 of 15

This screen is used to save the CURRENT fuel adjustment map TO one of five available map locations. The map
that is being copied TO must be Unlocked – otherwise a message will be displayed telling you that the map you
selected cannot be overwritten.

Note: When a map is copied, the Control Box will load the map copied TO to be the new current map.

Use the Up/Down and Left/Right Arrow keys to move the cursor to the map number you want to copy TO and
press “SEL”. The following confirmation message will be displayed:

Overwrite Map A

With Map B? Y

N

A” represents the map copied TO and “B” represents the current map to be copied FROM. If this is exactly what
you intend, use the Left Arrow to underscore “Y” and press “SEL”. Then the current map will be loaded into the
selected map number, the selected map number will become the current map, and the Control Box will return to the
Main Menu.

To quickly Lock or Unlock maps, move the cursor down to the Lock row, place the cursor under the L or U by the
desired map number, and press “SEL” to change a U (Unlocked) to an L (Locked) or vice versa.

Select Q to Quit and return to the Main Menu.


2.3

Map – Lock and ULock

Either Lock or ULock (UnLock) can be selected from the Map Menu to quickly lock or unlock the current map.
Move the cursor to the desired selection and press “SEL”. The box will return to the Main Menu and the current
map will be locked or unlocked when SEL is pressed.



3. Stats Menus

This Control Box has a new feature that allows real-time data to be displayed and captured. This feature can be useful for
tuning or for diagnostic purposes.

3.1 Stats: RUN/CAPTURE

Selecting Stats from the Main Menu will first display the following screen with real “Run-time” data (current
conditions):

Run 35/40

10.2EA

5500 MD

█ 10

1

st

line

Run “

Run” indicates display is in Run mode. If in capture mode, “Cap” will be displayed.

35

Input duty cycle in percent

40

Output duty cycle in percent

10.2

Current Boost Pressure

E

If “E” displayed, Exhuast Valve Fuel adjustment is on

A

If “A” displayed, Accelerator Pump Fuel adjustment is on

2

nd

line

5500

RPM (note, if the engine is shut off, the last recorded RPM may be displayed)

MD

Engine Load. LO, MD, or HI will be displayed.

These bars are a graphic display of LO, MD, or HI as shown below:

LO

MD

HI

10

Current Fuel Adjustment