Page 8 of 18
B. Main Menu
The Main Menu is shown below:
Main
Fuel Stats
Menu ExV
Map1U
The current selection is shown by the Right-Arrow and the cursor (underscore below the “F”). Use the arrow keys to
move the cursor. Move the cursor to the desired selection and press the “SEL” key to select the desired menu option from
one of the following:
Fuel
Go to the Fuel adjust menus (see Section 1).
Stats
Display runtime data, captured data, and recorded maximum data (see Section 3).
ExV
Menus for Exhaust Valve and Button setup (see Chapters VII and IX..).
Map
Go to the Map menu (see Section 2)
The current Map number is displayed as “Map1U”. This indicates that map number 1 is being used and it is Unlocked.
1. Fuel Adjust Menus
This selection is used to make fuel adjustments. There are five Fuel adjust screens (examples shown below). There are
two screens for adjusting fuel according to Boost pressure. There is one screen for adjusting Accelerator pump fuel.
The first fuel screen comes up after selecting Fuel and pressing a button. Go to the next fuel screen by pressing the “SEL”
button. After pressing the “SEL” on the last Fuel adjust screen, you will return to the Main Menu. Use the Left/Right
Arrow keys to switch between settings. Use the Up/Down Arrow keys to change the settings (if the current map is
unlocked). Sample Fuel adjust screens are shown below (actual rpm settings and number of screens may be different for
your model).
Fuel screen1:
M1L LO MD HI tr
3000 00 00 00 00
Fuel screen2:
M1L LO MD HI tr
5000 00 00 00 00
Fuel screen3:
M1L LO MD HI tr
6700 00 00 00 00
Fuel screen4:
M1L LO MD HI tr
7800 00 00 00 00
Fuel screen5:
M1L LO MD HI tr
8600 00 00 00 00
Boost screen1:
M1L -4 -2 0 +1
TboL 00 00 00 00
Boost screen2:
M1L 2 3 12 18
TboH 00 00 00 00
ACEL screen:
M1L AM DR Sens
ACEL 00 00 00
The fuel adjustment rpm ranges are blended as shown in the picture above. This allows for a broader range of adjustments
with fewer steps. Each fuel setting is centered at a particular rpm value, in this example: 3000, 5000, 6700, 7800,
8100rpm. Each region is blended with the region below and the region above it as shown. For example, if the rpm is at
4000, the adjustment value will be half the value of the 3000 setting plus half the value of the 5000 setting.