7 ℃/℉ interchange, 8 keep-warming mode, 9 pre-heating mode – CASO Germany EO27 User Manual
Page 62
caso EO 27
62
Press
one time, the light will bright in the oven, press
again the light turns off.
14.2.7
℃/℉ interchange:
Press
and
at the same time to change °C/°F display
14.2.8
keep-warming mode:
When the oven does not work, push the bottom
,and the default
mode
is set, push the bottom
to start the keep-warming
mode. The default temperature is 80 degree, and the keep-warming
bottom is lighten. To push the buttom
again to stop the keep-
warming mode, and the buttom goes out.
14.2.9
pre-heating mode:
When the oven does not work, push the bottom
,and the default
mode
is set, push the bottom
to start the preheating mode.
The default temperature is 180 degree, and the preheating bottom is
lighten. When the cavity reach 180 degree, the mode is stopped
automatically or to push the buttom
again to stop the keep-
warming mode, and the buttom goes out.
Please note
► E1 alarm is temperature sensor open circuit or short-circuit failure’s
showing code