beautypg.com

Salter Brecknell 6700U Series (USB) User Manual

Page 64

background image

64

67XXU USB/Serial Scale Service Manual

Command: W (57h 0dh), request current reading

Command: S (53h 0dh), request current status

Command: Z (5ah 0dh)

If ZERO function cannot be activated, it will return to current scale status.

Command: T (54h 0dh)

If TARE function cannot be activated, it will return to current scale status.

Response

^^^^^^^^U

1

U

2

U

3

U

4

U

5

H

1

H

2

H

3

H

4

---over capacity

_ _ _ _ _ _ _ _ U

1

U

2

U

3

U

4

U

5

H

1

H

2

H

3

H

4

---under capacity

- - - - - - - - U

1

U

2

U

3

U

4

U

5

H

1

H

2

H

3

H

4

---zero-point error

Note: U

1

U

2

U

3

U

4

U

5

is 1,2,3 or 5 bytes according to current unit: kg, lb, pcs, g, oz, lb:oz

W

1

W

2

W

3

W

4

W

5

W

6

U

1

U

2

U

3

U

4

U

5

H

1

H

2

H

3

H

4

---normal data

Note: (1) The decimal point position is determined by CONFG-PRIM.D
(2) If current unit is "lb:oz", the format will be similar with following:

W

1

W

2

W

3

lbW

4

W

5

W

6

oz H

1

H

2

H

3

H

4

Response

H

1

H

2

H

3

H

4

Response

Zero function is activated (simulate ZERO key) and it returns to current scale status.
H

1

H

2

H

3

H

4

Response

TARE function is activated (simulate TARE key), and then returns scale status.
H

1

H

2

H

3

H

4