Salter Brecknell 6700U Series (USB) User Manual
Page 42
![background image](/manuals/634898/42/background.png)
42
67XXU USB/Serial Scale Service Manual
COM1
(USB)
BUD.RT
1200
9600
Select COM1 baud rate
2400
4800
9600
19200
38400
BT.FMT
8N1
8N1
Select COM1 byte format
(1) 8N1=8 data bits, No parity check
bit, 1 stop bit
7O1
(2) 7O1=7 data bits, 1 Odd parity
check bit, 1 stop bit
7E1
(3) 7E1=7 data bits, 1 Even parity
check bit, 1 stop bit
OUT.MD
none
PRt.cd
Select COM1 output mode
(1) NONE=no communication
CONT
(2) CONT=continuously output
(3) PRINT=output after [PRINT] key
is pressed
CMD
(4) CMD=output after a request
command is received
PRT.CD
(5) PRT.CD= output after [PRINT]
key is pressed or request command
received
STABL
(6) STABL=Sends output
automatically after scale is stable.
Note: use PRINT or CMD to output
data, the scale must be stable
ST.NLD
**(7) ST.NLD=output after scale has
returned to zero range
(OTHER>NLD.RG) and is stable.
NLD
**(8) NLD= Output after scale has
returned to zero range
(OTHER>NLD.RG) and does not
wait for the scale to be stable.
Pr.nld
(9) PR.NLD= Manual push button
print once after scale is stable.
Scale has to return to zero range
(OTHER>NLD.RG) before another
push button print command can be
executed.
**Note: If PRINT, STABL, ST.NLD, LNLD or CMD are used to output data, the scale must be stable.