Page C-1

B.1.1.1 RECOGNIZED HOST COMMANDS

“P” - This command is sent to the indicator to print the indicated display. The

indicator will not respond if the scale is in motion, positive overload or
negative overload.

“Z” - This command is sent to the indicator to zero the scale. The indicator will not

respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it is not in gross mode or within the zero
range specified in F4 of the Setup Menu.

“T” - This command is sent to the indicator to tare the scale. The indicator will not

respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it displaying a negative gross value.

“G” - This command is sent to the indicator to revert to gross mode. The indicator

will not respond if the scale is in motion, positive overload or negative
overload. The indicator will also not respond if it is not in net mode.

“N” - This command is sent to the indicator to revert to net. The indicator will not

respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it is not in gross mode or a tare has yet to be
established.

“C” - This command is sent to the indicator to toggle among the configured units.

B.1.2 PRINT TICKET MODE

The Print Ticket Mode is designed specifically for a serial printer. Figure B-3 shows the fixed

format of the print ticket.

For printers with limited buffers, this mode supports DTR pin handshaking by enabling A7 in the

User Menu. The DTR pin from the serial printer is wired to the indicator’s RXD pin
which then functions as a CTS pin. Figure B-4 shows a suggested cable diagram
for interfacing to a serial printer. Refer to the printer’s user manual to confirm
whether or not it supports the DTR pin. The cable depicted in Figure B-4 can be
used even if the printer does not support the DTR pin.

NOTES:

1. The TARE and NET fields are not printed unless a tare has been established in the

system.

2. The ID number field is not printed if it is disabled in A4 of the User Menu.

3. The Time field is not printed if it is disabled in A8 of the User Menu.

4. The Date number field is not printed if it is disabled in A11 of the User Menu.

5. The PCS and APW fields are not printed unless the indicator is in piece count

mode.