CHAPTER 4: SETUP MENU DESCRIPTIONS AND PROCEDURES

4.1

SETUP MENU DESCRIPTIONS

This section provides more detailed descriptions of the selections found in the Setup Menu
Chart. Factory-set defaults are shown in bold with a checkmark (

).

Table 4-1 shows the selections that are not allowed for “Legal-for-Trade” applications:

NAME/CODE

DESCRIPTION

CODE/VALUE

F1
Graduations

Specifies

number of full-scale graduations. Value should be

consistent with legal requirements and environmental limits on the
useful system resolution.

500

1,000

1,500

2,000

2,500

3,000

4,000

5,000

6,000

8,000

10,000 12,000
20,000 30,000
40,000

50,000

F2
Span Gain

Span Gain is related to A/D integration time. The larger the span
gain, the higher the internal resolution, but the slower the update
speed. Note that the scale must be re-calibrated whenever this
parameter is altered. See Appendix C for more information.

25

50

75

 100

150

200

F3
Zero Track
Band

Selects the range within which the scale will automatically zero. Note
that the scale must be in standstill to automatically zero. Selections
are in Display Divisions.

0d
0.5d

1d
3d
5d

F4
Zero Range

Selects the range within which the scale may be zeroed. Note that
the indicator must be in standstill to zero the scale.

100%

1.9%

F5
Motion Band

Sets the level at which motion is detected by comparing the present
display update with the previous one. If motion is not detected for two
seconds or more, scale is in standstill and can process a Print or
Zero

command.

Maximum

value

varies

depending

on

local

regulations.

1d

3d
5d
10d

F6
Digital Filter

Averages weight readings to produce higher stability. The higher the
filter number, the greater the stability but the slower the response
time. Choose 8 or 16 unless a very fast response is needed. Use the
“Auto” setting to automatically determine the filter length as you are
weighing.

1

2

4

8

16

32

F7
Overload Limit

Selects the desired formula which determines the point at which the
indicator shows overload. All selections are based on the primary unit
selected in F8.

"FS" = Full scale in primary units.

FS
FS + 2%

FS + 1d
FS + 9d

F8
Calib. Unit

Selects the primary base unit to be used in the calibration process.
Also the default unit for normal operation.
"1" = primary unit is lb.

"2" = primary unit is in kg.

1

2