Salter Brecknell 200ES User Manual

Page 16

background image

3-3

F1
Grads

F2

Span Gn.

F4

Zero Range

F5
Mot. Band

F6
Dig. Filter

F7

Ovld. Limit

25 50 75 100 150 200

1 2 4 8

100% 1.9%

1d 3d 5d 10d

F8
Calib. Unit

F9
Dsp. Div.

lb kg

500 1000 1500 2000 2500 3000 4000 5000 6000 8000 10000 12000 20000 30000 40000 50000

0.5d 1d

3d

0d

5d

F3
Zero Band

0d 2% 1d 9d

1

2

5

F10
Dec. Pt.

F17
Span Calib.

Press ZERO

key to begin

F18
Cal. View

Press ZERO

key to begin

F19
Key-in Zero

Press ZERO

key to begin

F20
Key-in Span

Press ZERO

key to begin

0 0.0 0.00 0.000 0.0000 00

F16
Zero Calib.

Press ZERO

key to begin

F24
Piece Count Enable

0

1

Only pertains to the following models:

* 200E

* 200ES

Figure 3-2: Setup Menu Chart

3.2.4 NOTES ON THE SETUP MENU

1. There is an F21 sub-menu present that is for FACTORY USE ONLY!

2. Detailed descriptions of the setup menu parameters can be found in Chapter 4 of this

manual.

3. The User (“A”) menu sub-menus appear when scrolling left or right from the “F” menu.

4. Some selections shown are not available on all models in the series. Likewise,

additional selections may be available on other models in the series. See Chapter 4
for more information.

3.2.5 EXITING THE SETUP MENU – ABS ENCLOSURE

1. Power off the indicator.

2. On the rear panel, move the Setup/Calibration Switch back to its original position.

3. Power on the indicator. The display will go through a digit check, then settle into Normal

Operating mode. All front panel keys will now return to their normal mode of operation.