SECTION VII - CALIBRATION
7.4
TORCH OSCILLATION (OSC) AMPLITUDE CALIBRATION Cont.
1.
Select Weld Schedule Number ____ and verify that the FIRST PASS
it is programmed as follows:
LVL
1
TIME
0
PRI-AMP--BCK
100 100
PRI-PULSE-BCK
0.00 0.00
LVL
1
PULSE
OFF
ROT
OFF
PRI--IPM-BCK
0.00 0.00
LVL
1
PRI-WF-BCK
000 000
PRI-AVC-BCK
10.0 10.0
AVC MODE
CONT
LVL
1
OSC AMPL
.500
IN EXC OUT
0.5 0.5 0.5
PRE-PURGE-POST
3 3
UP-SLOPE-DOWN
0.0 0
ROT--DLY
CW 1.0
STR WFDLY STP
0.0 0.0
RETRACT
0.0
T/MODE
MAN
STLV
25
OSC
OFF
STR AVDLY STP
1.0 0.0
STR/ MODE
TOUCH
RESPONSE
3
2. Insure that the Torch is free to Oscillate without obstructions.
3. Set the WELD/TEST mode (RP or Panel) to TEST. Using Jog Keys center Torch
in the middle of its stroke.
4. Using the Dial Caliper prepare to measure the total movement of the Torch from
its furthest IN position (toward the Head) to its furthest OUT position. How this
can be done will vary from Weld Head Model to Weld Head Model.
5. Press Sequence Start and after prepurge measure the full Oscillator movement. It
should be 0.500 inch +/- 0.005. If out of tolerance adjust TR4 on the center plate.
6. When measurement and adjustment is complete press All Stop.
7.6