MODEL 227
OPERATION MANUAL
Doc # 740063 Rev E
SECTION II - SPECIFICATION
2.3
MULTI-LEVEL FUNCTIONS - The following functions can be programmed to
change value during a given weld sequence.
FUNCTION
POSSIBLE CHANGES
LEVEL TIME
= 1 to 99 levels
PRIMARY CURRENT
= 1 to 99 levels
BACKGROUND CURRENT
= 1 to 99 levels
PRIMARY PULSE TIME
= 1 to 99 levels
BACKGROUND PULSE TIME
= 1 to 99 levels
PULSE MODE (ON/OFF/SYNC)
= 1 to 99 levels
PRIMARY ROTATION RPM
= 1 to 99 levels
BACKGROUND ROTATION RPM
= 1 to 99 levels
ROTATION MODE (CONT/STEP/OFF)
= 1 to 99 levels
PRIMARY WIRE FEED SPEED
= 1 to 99 levels
BACKGROUND WIRE FEED SPEED
= 1 to 99 levels
AVC MODE
= 1 to 99 levels
PRIMARY AVC
= 1 to 99 levels
BACKGROUND AVC
= 1 to 99 levels
OSC AMPLITUDE
= 1 to 99 levels
OSC DWELL and EXCURSION TIMES
= 1 to 99 levels
2.4
NON-PROGRAMMABLE FUNCTIONS
WIRE FEED MODE SWITCH
= ON/OFF
SYSTEM MODE KEY SWITCH
= PROGRAM/OPERATE/LOCK
MANUAL PURGE = ON/OFF
2.5
AMBIENT TEMPERATURE RANGE - 32 F (0 C) to 110 F (45 C).
2.6
CABLE OPERATING DISTANCE LIMITS - Standard = 50 ft (15.2 m)
Maximum = 100 ft (30.5 m)
The standard distance consists of a 40 ft Pipe Weld Head Adapter cable and a 10 ft
Weld Head cable combined together. The maximum distance is achieved by
adding extension cables to the standard cables.
The above are considered normal limits and using a standard M227/207-CW or
M207-CW Cooling Unit Option. With special options, greater distances can be
achieved.Consult with an AMI technical representative for more information.
2.4