Programmable ignitions are shipped with additional leads coming out of the ignition. These leads allow the ignition to
control other features. To program these features, follow the instructions in the programming kit.

GREEN – Tachometer output, 12V, 1 pulse per rev, square wave.
PURPLE – Programmable launch limiter. Apply +12V this wire to activate. See below.
BLUE – Optional 2-amp switch to ground, referenced as “RPM Switch 1” in PC Software.
WHITE – Optional 2-amp switch to ground, referenced as “RPM Switch 2” in PC Software.

The Launch RPM is programmable (preset to 3000 rpm) and can be wired to a separate switch (not included) for a “two
step/low side” launch limiter. Apply +12V to this wire to activate. The PURPLE wire can be connected directly to the
blue wire at the Teryx brake light relay (located next to the battery). The limit can be adjusted in CurveMaker software.

The White & Blue 2-amp switches can be used to activate a solenoid or relay. Connect the relay with hot +12v wired to
one side of the relay coil, and the other side connected to White or Blue. When the rpm activates the switch, it will be
grounded inside the ignition box, causing current to flow through the relay coil. DO NOT connect any device which
requires more than 2 Amps (Amps=Volts/Resistance). See attached wiring diagram for wiring the relay.


Troubleshooting


Troubleshooting the Dyna ignition is simple. If the vehicle will not start or run at all, reinstall the stock ignition. If this
fixes the problem, then the Dyna ignition should be returned to Dynatek for testing. If this does not fix the problem, then
the problem is somewhere else on the vehicle. Follow the troubleshooting procedures outlined in your shop manual.

If the engine runs, but poorly, put the stock ignition back on the vehicle. If this fixes the problem, reinstall the Dyna
ignition. If you are using non stock plug wires, plug cap, ignition coil, spark plug, or stator, replace them with OEM units.
If this doesn't fix the problem, the ignition should be returned for testing. If the problem persists when using the stock
ignition then the problem is external to the Dyna ignition.
















WARNING:

Installation of a grounded tether kill switch to the ignition coil signal will

damage the CDI and void the warranty.

12V DC-CDI ( Teryx 750 / Prairie 650 / etc.): Use a normally closed tether kill switch connected in series with
the +12V input (BROWN) to the ignition. When the tether is removed, it should disconnect the +12V power to
the ignition. If a normally closed tether kill switch cannot be located, then a grounded tether can be used to
ground the pickup signal (Black/White wire at the ignition module)