beautypg.com

Tap ac switching characteristics, Tap timing and test conditions – Cypress CY7C1294DV18 User Manual

Page 13

background image

CY7C1292DV18
CY7C1294DV18

Document #: 001-00350 Rev. *A

Page 13 of 23

TAP AC Switching Characteristics

Over the Operating Range

[13, 14]

Parameter

Description

Min.

Max.

Unit

t

TCYC

TCK Clock Cycle Time

50

ns

t

TF

TCK Clock Frequency

20

MHz

t

TH

TCK Clock HIGH

20

ns

t

TL

TCK Clock LOW

20

ns

Set-up Times

t

TMSS

TMS Set-up to TCK Clock Rise

5

ns

t

TDIS

TDI Set-up to TCK Clock Rise

5

ns

t

CS

Capture Set-up to TCK Rise

5

ns

Hold Times

t

TMSH

TMS Hold after TCK Clock Rise

5

ns

t

TDIH

TDI Hold after Clock Rise

5

ns

t

CH

Capture Hold after Clock Rise

5

ns

Output Times

t

TDOV

TCK Clock LOW to TDO Valid

10

ns

t

TDOX

TCK Clock LOW to TDO Invalid

0

ns

TAP Timing and Test Conditions

[13]

Notes:

13. Test conditions are specified using the load in TAP AC test conditions. t

R

/t

F

= 1 ns.

14. t

CS

and t

CH

refer to the set-up and hold time requirements of latching data from the boundary scan register.

(a)

TDO

C

L

= 20 pF

Z

0

= 50

GND

0.9V

50

1.8V

0V

ALL INPUT PULSES

0.9V

Test Clock

Test Mode Select

TCK

TMS

Test Data-In
TDI

Test Data-Out

t

TCYC

t

TMSH

t

TL

t

TH

t

TMSS

t

TDIS

t

TDIH

t

TDOV

t

TDOX

TDO

[+] Feedback