C — Reversing valve output (O/W2/B) is energized when COOL mode is

selected.
Default is C.
Option 11 — Deadband Setting Between Heat & Cool
This option is not available on Heat Only and Cool Only systems. This selection

is to allow the installer to choose how much differential exists between the

heating and cooling setpoints. Allowable selections are 1−6.
Default is 2.
Option 12 — Smart Recovery
Smart Recovery OF (off) means setpoints change precisely at setback recovery

time. Thirty, 60, or 90 selects the number of minutes recovery starts before

programmed recovery time. Recovery takes place smoothly during the selected

recovery time, ending at the recovery time and temperature which is

programmed. Not available with non−programmable thermostats or when

thermostat is configured as non−programmable.
Default is 90.
Option 13 — Room Air Temperature Offset Adjust
The number of degrees to be added to the displayed temperature to calibrate or

deliberately miscalibrate the measured room temperature ( −5 to +5

_).

Default is 0.
Option 15 — Enable Auto Mode
This selection is not available if the thermostat is configured as Heat Only or

Cool Only in Option 1. This allows the homeowner to select auto changeover

mode in addition to heat and cool. This allows the thermostat to automatically

change between heating mode and cooling mode when sufficient demand for

heating or cooling exists.