24
WHILE IN CONFIGURATION MODE
The option number is displayed in the heat setpoint location and the
configuration setting is displayed in the cool setpoint location. On the
TP−PAC/PHP (programmable) models, a box will surround the option number.
The mode button is used to move the box between the two displayed values. The
soft keys below the listed values may also be used to move the box between
selected values. The value inside the box is changed by using the UP/DOWN
buttons. On the TP−NAC/NHP (non−programmable) models, one of the values
will be flashing. The mode button is used to change which value is flashing or
the Home and Sleep buttons may also be used to select which value to flash. The
value that is flashing is changed by using the UP/Down buttons. All changes
made are saved at the time of selection and will be saved in the event of the 3
minute time−out or when installer exits from configuration menu.
Configuration Options —Selection
Option 01 — Equipment Type
HP model — Range: HP, AC, H, C, H2, A2.
AC model — Range: AC, H, C.
HP — operates a single−speed heat pump with a fan coil.
AC — operates a single−speed AC.
H
— operates a heat−only system. Furnace or fan coil only;
no outdoor unit.
C
— operates a cool only−system. Outdoor AC unit with an
indoor fan coil with no strip heaters.
A2 — 2−stage air conditioner with a furnace or fan coil.
H2 — 2−stage heat pump with a fan coil.