background image

Corrective
Action:

The issue occurs
because of any of
the following
causes:

The driver is not native in the operating system.
To resolve the issue, press to install the RAID device
driver during installation.

The virtual disks are not configured properly.
To resolve the issue, enter the BIOS Configuration Utility
( ) to configure the virtual disks. For procedures to
configure the virtual disks, see the topic

Management

Applications For PERC Cards

.

The controller BIOS is disabled.
To resolve the issue, enter the BIOS Configuration Utility
( ) to enable the BIOS. For information on
configuring virtual disks, see the topic

Management

Applications For PERC Cards

.

Physical Disk Issues

Physical Disk In Failed State

Issue:

One of the physical disks in the disk array is in the failed state.

Corrective
Action:

Update the PERC cards to the latest firmware available on dell.com/support.

Unable to Rebuild A Fault Tolerant Virtual Disk

Issue:

Cannot rebuild a fault tolerant virtual disk. For more information, see the alert log for virtual
disks.

Corrective
Action:

The replacement disk is too small or not compatible with the virtual disk. Replace the failed
disk with a compatible good physical disk with equal or greater capacity.

Fatal Error Or Data Corruption Reported

Issue:

Fatal error(s) or data corruption(s) are reported when accessing virtual disks.

Corrective
Action:

Contact Dell Technical Support.

Physical Disk Displayed As Blocked

Issue:

One or more physical disks is displayed as Blocked and cannot be configured.

Corrective
Action:

Update the PERC cards to the latest firmware available on dell.com/support.