Dell PowerVault LTO3-060 User Manual

Page 23

background image

c. Verify that the Fault LED is flashing.

n

If the Fault LED is flashing, then the dump is in RAM.

n

If the Fault LED is not flashing, repeat the Service Function 2 procedure.

d. Press the Unload button once per second until you exit from Service mode and the Ready light comes ON solid.

Executing Service Function 3: Reserved for trained service personnel

Executing Service Function 4: Copy dump to flash

     

1. Ensure there is no cartridge in the drive.

Note:

If a cartridge is loaded in the drive, depression of the Unload button is interpreted as an unload request and the drive will ignore the second and third
depressions. The drive cannot be put into Service mode while a cartridge is loaded.

2. Press and hold the Unload button until the Ready LED begins flashing rapidly indicating Service Function 1 has been accessed. The status LEDs will be in one of

the following states.

3. Press the Unload button 3 times to access Service Function 4. The status LEDs will be in one of the following states.

Key:

= OFF

= Flashing slowly

= Flashing rapidly

LED icon

LED state

Service Function 1; no drive dump

in memory

Service Function 1; drive dump in

RAM

Service Function 1; drive dump in

flash memory

Key:

= OFF

= ON

= Flashing slowly

= Flashing rapidly

Important

The drive will timeout if the next step is not performed within 15 seconds.

NOTE: You can only copy dump to flash if there is a dump in RAM.

LED icon

Service Function 4

Service Function 4; drive dump in

RAM*

Service Function 4; drive dump in

flash memory