Dell PowerEdge C6220 User Manual
Page 33
33
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X
BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm
Probe List
Status Column
Displays the status of the temperature sensor.
Probe Name Column
Displays the temperature sensor name.
Typical temperature probes:
• MEZZ1 Temp
• CPU1 Temp
• CPU2 Temp
• DIMM ZONE 1 Temp
• DIMM ZONE 2 Temp
• PCH Temp
• Inlet Temp
If there are GPGPU(s) installed in the system, then one
or more (according to the GPGPU card number) of the
following temperature probes will display:
• MIC Temp #
• K10 Temp #
• K20 Temp #
• M2090 Temp #
NOTE:
The # will appear between 1 to 4. If a dual-core
GPGPU card is installed (e.g. nVidia TESLA K10), two
temperature probes will display for each dual-core GPGPU
card.
Reading Column
Displays the temperature sensor reading.
Lower Non-Recoverable
Column
Displays the temperature sensor lower non-recoverable
threshold.
Lower Critical Column
Displays the temperature sensor lower critical threshold.
Lower Non-Critical
Column
Displays the temperature sensor lower non-critical
threshold.
Table 1-18. Temperature Sensor Readings
Items
Description