Ac electrical characteristics, Electrical characteristics – Cypress CY7C1422BV18 User Manual
Page 21
CY7C1422BV18, CY7C1429BV18
CY7C1423BV18, CY7C1424BV18
Document #: 001-07035 Rev. *D
Page 21 of 30
I
DD
V
DD
Operating Supply
V
DD
= Max,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
CYC
200MHz
(x8)
600
mA
(x9)
600
(x18)
600
(x36)
665
167MHz
(x8)
500
mA
(x9)
500
(x18)
500
(x36)
560
I
SB1
Automatic Power down
Current
Max V
DD
,
Both Ports Deselected,
V
IN
≥ V
IH
or V
IN
≤ V
IL
f = f
MAX
= 1/t
CYC
,
Inputs Static
300MHz
(x8)
325
mA
(x9)
325
(x18)
345
(x36)
375
278MHz
(x8)
310
mA
(x9)
310
(x18)
325
(x36)
355
250MHz
(x8)
300
mA
(x9)
300
(x18)
310
(x36)
330
200MHz
(x8)
285
mA
(x9)
285
(x18)
290
(x36)
300
167MHz
(x8)
275
mA
(x9)
275
(x18)
275
(x36)
285
AC Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
+ 0.2
–
–
V
V
IL
Input LOW Voltage
–
–
V
REF
– 0.2
V
Electrical Characteristics
(continued)
DC Electrical Characteristics
Over the Operating Range
[12]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit