Dell PowerEdge M610 User Manual
Page 113
About Your System
113
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory single-bit
error (SBE) logging and
does not log anymore SBEs
until the system is
rebooted. "##" represents
the DIMM implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E2112 Memory spared
on DIMM ##.
Power cycle
AC.
The system BIOS has
spared the memory because
it has determined the
memory had too many
errors. "##" represents the
DIMM implicated by the
BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC
The system BIOS has
disabled memory mirroring
because it has determined
that half of the mirror has
had too many errors. "##
& ##" represents the
DIMM pair implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
I1911 LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912 SEL full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
of the error messages,
then remove AC power to
the system for 10 seconds
to clear the SEL and
restart the system.
Table 1-26. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions