beautypg.com

Dell PowerEdge M610 User Manual

Page 113

background image

About Your System

113

E2111 SBE log

disabled on
DIMM ##.
Reseat DIMM.

The system BIOS has

disabled memory single-bit

error (SBE) logging and

does not log anymore SBEs

until the system is

rebooted. "##" represents

the DIMM implicated by

the BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

Blade Memory" on

page 319.

E2112 Memory spared

on DIMM ##.
Power cycle
AC.

The system BIOS has

spared the memory because

it has determined the

memory had too many

errors. "##" represents the

DIMM implicated by the

BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

Blade Memory" on

page 319.

E2113 Mem mirror

OFF on DIMM
## & ##.
Power cycle
AC

The system BIOS has

disabled memory mirroring

because it has determined

that half of the mirror has

had too many errors. "##

& ##" represents the

DIMM pair implicated by

the BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

Blade Memory" on

page 319.

I1911 LCD Log Full.

Check SEL to
review all
Errors.

LCD overflow message. A

maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912 SEL full.

Review &
clear log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for details

of the error messages,

then remove AC power to

the system for 10 seconds

to clear the SEL and

restart the system.

Table 1-26. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions