Dell PowerEdge R410 User Manual
Page 49
About Your System
49
The following
DIMMs should
match
in
geometry:
x,x,...
Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of
data lanes.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 119.
The following
DIMMs should
match
in rank
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
match
in size
and geometry:
x,x,...
The following
DIMMs should
match
in size
and rank count:
x,x,...
Thermal sensor
not detected on
x
A memory module without a
thermal sensor is installed in
the specified memory slot.
Replace the memory
module. See "System
Memory" on page 119.
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57. If the problem
persists, replace the system
battery. See "System Battery"
on page 130.
Table 1-3.
System Messages (continued)
Message
Causes
Corrective Actions