beautypg.com

Dell PowerEdge R410 User Manual

Page 49

background image

About Your System

49

The following

DIMMs should

match

in

geometry:

x,x,...

Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of
data lanes.

Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 119.

The following

DIMMs should

match

in rank

count:

x,x,...

The following

DIMMs should

match in size:

x,x,...

The following

DIMMs should

match

in size

and geometry:

x,x,...

The following

DIMMs should

match

in size

and rank count:

x,x,...

Thermal sensor

not detected on

x

A memory module without a
thermal sensor is installed in
the specified memory slot.

Replace the memory
module. See "System
Memory" on page 119.

Time-of-day

clock stopped

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 150.

Time-of-day not

set - please run

SETUP program

Incorrect Time or Date
settings; faulty system
battery.

Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 57. If the problem
persists, replace the system
battery. See "System Battery"
on page 130.

Table 1-3.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 49 Tuesday, March 31, 2009 5:26 PM