beautypg.com

Troubleshooting guide, Wiring diagram – Cleveland Range KDL-SH User Manual

Page 19

background image

TROUBLESHOOTING GUIDE

This section contains information intended for use by Authorized Service Personnel only.

PROBLEM

A/

Kettle heats too slowly or does not come to a boil.

Probable Cause

Remedy

1.

Inadequate steam flow.

Check for correct steam using chart below.

If kettle is connected to a steamer and powered by a generator the units
should be operated sequentially (kettle boiling first, then start steamer).

2.

Steam trap not operating properly. The trap should open periodically to dump condensate, then close.

If it does not open or close it should be cleaned or replaced.

3.

Food batches are not always

When checking make certain that the original state (ie. fresh or frozen)

the same.

and quantity of food product is the same.

PROBLEM

B/

The trunnion housing leaks steam.

Probable Cause

Remedy

1.

Trunnion "O" rings are worn.

Replace "O" rings

PROBLEM

B/

The steam trap makes a banging noise when steam applied to cold kettle.

Probable Cause

Remedy

1.

Kettle condensate has not

On all tilting models the condensate should be drained from the cold kettle. This is

been drained.

done before steam is applied using the drain cock valve on the bottom of the kettle.

WIRING DIAGRAM

Power Tilt Units Only
115 Volts, 1PH, 50/60HZ

This manual is related to the following products: