Sticker to indicate measuring unit

2.3 Limit outputs
The device provides 2 relay limit outputs. Output trigger either at ≥

displayed value or ≤ limit is defined by HIGH or LOW configuration.

The outputs can be configured as time delay or hysteresis.

Limit outputs as time delay

Time delay parameterization is within the range from 00 to 99 s and

will be effective both at limit output power on and off.

Delay

Delay

Delay

Delay

Relay 1 =

HIGH

Relay 2 =

LOW

Limit 1

Limit 2

Asymmetrical hysteresis

Hysteresis is configured in display units from 0 to 9999 and only ef-

fective at limit output power off.

Hysteresis

Hysteresis

Relay 1 =

HIGH

Relay 2 =

LOW

Limit 1