6configuration, Table of general parameters, 2 table of work parameters – Baumer FHDx14 IO User Manual
Page 12
en_BA_FNDx14_FHDx14_IO.doc
12/14
Baumer Electric AG
12.04.2013/hem
Frauenfeld, Switzerland
6
Configuration
6.1
Table of general parameters
S
P
D
U
n
a
m
e
S
P
D
U
i
n
d
e
x
N
u
m
b
e
r
o
f
B
y
te
s
F
o
rm
a
t
R
a
n
g
e
o
f
v
a
lu
e
s
R
/W
C
o
m
m
e
n
ts
General information on sensors
Vendor Name
0X10
18
String
ASCII
R
“Baumer Electric AG“ for all sensors
Product Name
0X12
22
String
ASCII
R
Corresponds to Baumer article description
Product ID
0X13
8
String
ASCII
R
Corresponds to Baumer article number
Serial Number
0X15
4
String
ASCII
R
Baumer P-Code
Firmware Revision
0X17
8
String
ASCII
R
Baumer Firmware Revision
Application Specific
Name
0X18
8
-
-
R/W
8 Byte at customer disposal
6.2
Table of work parameters
S
P
D
U
n
a
m
e
S
P
D
U
i
n
d
e
x
N
u
m
b
e
r
o
f
B
y
te
s
F
o
rm
a
t
R
a
n
g
e
o
f
v
a
lu
e
s
R
/W
C
o
m
m
e
n
ts
Teach-in and switching points
Switching points
work
0X40
4
Switching point A (HB, LB)
Switching point B (HB, LB)
50…400
R/W Distance information on switching points,
calculated from the information on Teach-
in position interim
Teach-in positions
interim
0X41
4
Teach-in Position A (HB, LB)
Teach-in Position B (HB, LB)
50…400,
65535
R
Distance information on Teach-in position
Sensor functions
Teach function
0X60
1
0 = One point Teach-in
(Reference position)
2 = Two point Teach-in
(ON/OFF-position)
0.2
R/W Selection of Teach mode
Nominal value
quality parameter
0X65
1
1..8
R/W Provided the internal quality parameter
drops below this threshold the switching
output is set.
Quality parameter
0X66
1
1..8 or 255
R
Output functions
Output delay
function
0x71
1
Byte 0 (Subindex 1)
0 = no delay
1 = on delay
2 = off delay
3 = minimum pulse
4 = single shot positive edge
5 = single shot negative edge
0…5
R/W Choose delay funciton
Output delay time
0x72
2
Byte 1…2, time in 1ms
0…1000
R/W Delay time