10 SAFETY
10.1 Safety Features
The following chapter describes the safety features of the DENEX MICRO. Make regular
checks to verify the function of these features.
10.1.1 Power Control
To power off the sensor, unplug the power connection.
10.1.2 Visible Warning-LED
The green LED is the POWER-LED, which indicates that the laser is on!
Never move or adjust the sensor when the green LED is on!
11 MAINTENANCE AND REPAIRS
Before any adjustments or maintenance is carried out on the DENEX MICRO, make sure
to follow the instructions below:
Switch off the power by removing the power plug.
11.1 Maintenance at Regular Intervals
The only maintenance on the sensor which is allowed by non-DENEX Sensor authorized
personnel is cleaning the glass window, but only after first turning the sensor off.
- Clean the glass aperture with alcohol
- Remove any loose pieces of paper that can produce false counts
- Check that the beam stopper is in place and that it is not covered with dust
CAUTION
Use of controls or adjustments other than those
specified
herein may result in hazardous radiation exposure.
Diode laser power up to 1 mW at 670 nm can be accessible in the interior.
Avoid exposure to beam!