4 dip-switch settings – Baumer BA DenexMicro User Manual
Page 13
User Manual DENEX MICRO
13/24
Baumer Electric AG
Version 2013-02, V1.6
www.baumer.com
Frauenfeld, Switzerland
6.4 DIP-Switch Settings
An 8-pole DIP-switch can be reached via the lid on top of the sensor. Unscrewing the
screw opens the lid.
The software functions can be controlled via the DIP switches.
DIP-Switch positions
= OFF
= ON
DIP-switches 1-4 are reserved for factory
DIP-switches 5-8 are for selecting operation mode
All in OFF-position is the default setting.
DIP-Switches
5 6 7 8
Mode 0 =
Default
Counting mode: 15% Blocking, short Back-Edge Check, Output 5ms
Mode 1
Thick newspapers: 30% Blocking time, long Back-Edge Check. Output 5 ms
Mode 2
Counting mode: speed pulses, Blocking pulses 5, Back-edge 16, Output: 5ms
Mode 3
Counting mode: speed pulses, Blocking pulses 5, Back-edge 5,Output: 20ms
Mode 4
Thick newspapers, Blocking pulses 20. Back-edge 16, Output: 5ms
Mode 5
Edge detecting: fixed trig, Blocking 15%,No back-edge check, Output: 5ms
Mode 6
Gripper Pulse mode: For gripper conveyors, Blocking 15%, Output 20 ms
Mode 7
Cut edge first mode: Blocking 30 %, Back-edge 15%, Output 5 ms
Mode 8
Counting mode: Speed pulses, Blocking 10, Back-edge 16, Output 5ms
Mode 9
Commercial: Fixed trig, No Blocking, No Back-edge, Output 20 ms
Mode 10
Counting mode: 15% Blocking, short Back-Edge Check, Output 20ms
Mode 11
Counting mode: speed pulses, Blocking pulses 5, Back-edge 16, Output: 5ms
Laser power save mode is activated in all Counting/newspaper modes.
This means the laser power will be reduced after a 60 seconds gap.