beautypg.com

4 dip-switch settings – Baumer BA DenexMicro User Manual

Page 13

background image

User Manual DENEX MICRO

13/24

Baumer Electric AG

Version 2013-02, V1.6

www.baumer.com

Frauenfeld, Switzerland

6.4 DIP-Switch Settings

An 8-pole DIP-switch can be reached via the lid on top of the sensor. Unscrewing the
screw opens the lid.
The software functions can be controlled via the DIP switches.

DIP-Switch positions

= OFF

= ON


DIP-switches 1-4 are reserved for factory
DIP-switches 5-8 are for selecting operation mode

All in OFF-position is the default setting.

DIP-Switches

5 6 7 8

Mode 0 =
Default

Counting mode: 15% Blocking, short Back-Edge Check, Output 5ms

Mode 1

Thick newspapers: 30% Blocking time, long Back-Edge Check. Output 5 ms

Mode 2

Counting mode: speed pulses, Blocking pulses 5, Back-edge 16, Output: 5ms

Mode 3

Counting mode: speed pulses, Blocking pulses 5, Back-edge 5,Output: 20ms

Mode 4

Thick newspapers, Blocking pulses 20. Back-edge 16, Output: 5ms

Mode 5

Edge detecting: fixed trig, Blocking 15%,No back-edge check, Output: 5ms

Mode 6

Gripper Pulse mode: For gripper conveyors, Blocking 15%, Output 20 ms

Mode 7

Cut edge first mode: Blocking 30 %, Back-edge 15%, Output 5 ms

Mode 8

Counting mode: Speed pulses, Blocking 10, Back-edge 16, Output 5ms

Mode 9

Commercial: Fixed trig, No Blocking, No Back-edge, Output 20 ms

Mode 10

Counting mode: 15% Blocking, short Back-Edge Check, Output 20ms

Mode 11

Counting mode: speed pulses, Blocking pulses 5, Back-edge 16, Output: 5ms

Laser power save mode is activated in all Counting/newspaper modes.
This means the laser power will be reduced after a 60 seconds gap.