Figure 5.2.1.2 Electrical connection, common 24V-supply. Current sink (NPN).
 
 
Figure 5.2.1.3 Electrical connection, separate supply for power and pulse.
5.2.2 Speed Sensor Input
There is a possibility to connect an input signal from a speed sensor, such as an encoder, 
in order to give information of conveyor speed. The input can be used to obtain a fixed 
blocking distance. In Mode 7 (see chapter 6, “SOFTWARE FUNCTIONS”) the input signal 
is used as a control signal, if high, the blocking time is long, if low, the blocking time is 
short. Normally, the dynamic blocking is used with equally good results. There are three 
different modes of blocking, see chapter 6, ”SOFTWARE FUNCTIONS”. 
The input is opto-isolated so that there is a separation between the sensor’s and the pulse 
generator’s grounds. 
 
The input should be min. 4.5V and max. 28V. 
The maximum allowed frequency is 2.5 kHz. 
 
Figure 5.2.2.1 Input stage for speed sensor input.