Manual_GK473_S7_Profibus_EN.doc 13/32

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany


In this window enter only the Node ID which has to be identical to that previously set at the gateway’s
two rotary switches (Example: 42).

Close window by click on OK .
Drag module “16bit I/O” of GK473 from the hardware catalogue to the window „location /module“ in the
left corner. Upon double click on the newly created line the window of module “16bit I/O” will reopen.
Enter port addresses for input and output data. Different from the screenshot the example is using
identifiers (addresses) 20 to 35.


3.4 Parameterization

Upon double click on the gateway icon of the bus rail in window HW-config the window „Properties DP-
Slave“ will open. You may proceed alterations of slave number and diagnostic address. The Profibus
node ID has yet been entered above and therefore should already be the correct one.