Edge Lighting Plaza Large Dimmable User Manual
Page 2
G
N
L
G
N
L
G
N
L
G
N
L
G
N
L
G
N
L
2
D
10
8
8
8
8
8
6
E
LAMP
SOCKET
MIRROR
HOUSING
MOUNTING
PLATE
3MM ALLEN
WRENCH
M6 SCREW
13
14
13
14
8
6: Install the conduit connector (not provided) to mounting
plate hole. Feed the power line through the conduit
connector into the mounting plate.
8: Line up the mounting plate holes with the anchors and
secure it to the anchors with the six #8-32 screws
provided.
9: Make sure that the mounting plate is grounded in
accordance with local electrical codes.
10: Connect the hot, neutral power wires into the wago
connector.
NOTE: If necessary, push the tab down and then pull the Wago
connector for a quick disconnect.
NOTE:
Omit steps 11 & 12 for non-dimming wiring.
11: For dimming, run the violet and gray wires from the
dimmer each ballast. The wires must be solid copper
(refer to the dimmer instruction for more details).
12: Branch the violet wire to the (+) & the gray wire (-)
terminals of each ballast respectively.
Use
MAX 24
Watt Type T5 HO,
Linear Fluorescent Lamp For the top and bottom Socket.
Use
MAX 39
Watt Type T5 HO,
Linear Fluorescent Lamp For the right and left Socket.
13: Line up the lamp pins on both sides with the opening on the
socket.
14: Insert the lamp pins all the way into the sockets and turn
the lamp to lock it in place. Repeat this step for the other
lamp.
15: Place the mirror housing onto the mounting plate and
secure it in place by tightening the four #8 screw on the
top and bottom of the mirror housing into the mounting
plate.
CAUTION:
To reduce risk of a burn or electrical shock during
lamping, disconnect the power to the fixture.
VIOLET
GRAY
(+) Dimming
(-) Control
GREEN
G
N
WHITE
BLACK
L
11
BALLAST
12
G
N
L
10
TAB
WAGO
CONNECTOR
G
N
L
#8-32 SCREW
MOUNTING
PLATE
NOTE:
NEMA fluorescent lamp manufacturers recommend to
reduce possible flicker or instability when new dimming systems
are comissioned, lamps should be operated at the ballast's
maximum light output setting overnight (approximately
12 hours).