FIG. 17

UP button

Display

RECHARGE button

SELECT button

DOWN button

FIG. 16

When the transformer is plugged into the electrical

outlet, a model code and a test number (example:

J2.0), begin to flash in the faceplate display. Then,

“12:00 PM” and the words “PRESENT TIME" begin to

flash.
NOTE: If “- - - -” shows in the display, press the

p

UP

or

q

DOWN button until the model code

(“o27” for Model EP27 or “o30” for Model

EP30) shows in the display. Then, press the

SELECT button to set, and change to the

flashing “PRESENT TIME" display.

SET TIME OF DAY

If the words “PRESENT TIME" do not show in the dis-

play, press the SELECT button until they do.
1. Press the

p

UP or

q

DOWN buttons to set the

present time. Up moves the display ahead; down

sets the time back. Be sure AM or PM is correct.

NOTE: Press buttons and quickly release to slowly

advance the display. Hold the buttons down

for fast advance.

FIG. 18

SET WATER HARDNESS NUMBER

1. Press the SELECT button once again to display a

flashing “25” and the word “HARDNESS”.

2. Press the

p

UP or

q

DOWN buttons to set your

water’s hardness number.
NOTE: If your water supply contains iron, compen-

sate for it by adding to the water hardness

number. For example, assume your water is

20 gpg hard and contains 2 ppm iron. Add 5

to the hardness number for each 1 ppm of

iron. In this example, you would use 30 for

your hardness number.

20 gpg hardness

2 ppm iron x 5 = 10 +10

(times)

30 HARDNESS NUMBER

NOTE: If you use potassium chloride (KCl) salt

instead of sodium chloride (NaCl) salt in this

softener, increase the hardness setting by

25%. For example, if you will be using KCl

and your water supply’s hardness is 20 gpg,

set the softener to 25 gpg.