METHOD 1. - MANUAL CALIBRATION - CAL
 
This procedure requires a reference boat speed with which to 
compare the Network QUAD units displayed boat speed. For 
example, another boat with an accurate calibrated log, or if 
the top speed of the boat is known this value can be entered 
during a sea trial to correct the 
displayed value. 
 
NOTE: The accuracy of this method is depend
ent upon the
accuracy of the reference boat speed. 
 
The example below shows a displayed boat speed of 5.2 
knots, the boat speed is known to be 6.0 knots. The 
displayed value is adjusted to read 6.0 knots. 
IMPORTANT NOTE: This method of calibration must not be 
carried out at boat speeds of LESS THAN 3 KNOTS as 
inaccurate values can be entered into the units memory. If 
the speed and log are not functioning correctly then enter a 
calibration value of 5.3 to 6.2 and then re-enter the correct 
calibration value as described below. 
 
 
 
Press SPEED key 
to display current 
boat speed.
Press SETUP key 
three times to 
display CAL.
Press ENTER key 
to adjust the 
displayed value.
Use
S or T to
change the value.
Press ENTER to 
store the new 
value in memory.
Press SPEED key 
to complete the 
change. 
 
 