beautypg.com

Using the timer – B&G Network Compass User Manual

Page 12

background image

NETWORK COMPASS USER MANUAL

USING THE TIMER


Pressing the TIMER key enters the timer display mode, which is shown by the presence
of a flashing colon.

MODE

TIMER

LOCK

SETUP

LIGHTS

ENTER

Network COMPASS

30

20

10

30

20

10












The timer can be set to any required value to a maximum time period of 99 hours 59
minutes. The analogue bar graph shows the time left, in minutes, from 30 minutes before
time zero (bar graph on the left) to 30 minutes after (bar graph on the right).

The unit will also beep to indicate the passage of set units of time, the number and
frequency of beeps depending on the time left to time zero. There are no beeps after time
zero. The beep sequences are shown in the table below:

Beeps begin at

Beeps end at

Number of

beeps

Frequency

< 60 hours

1 hour

5

every hour

< 1 hour

=>10 minutes

4

every 10 minutes

< 10 minutes

=> 1 minute

3

every minute

< 1 minute

=> 10 seconds

2

every 10 seconds

< 10 seconds

>0

1

every second

= 0

>-10 seconds

continuous

for 10 seconds


This means that for the example given above of 1 hour 48 minutes the following beeps
will occur:

5 beeps at 1:00

4 beeps at 0:50; 0:40; 0:30; 0:20; 0:10

3 beeps at 0:09; 0:08; 0:07; 0:06...0:01

2 beeps at 0:00:50; 0:00:40...0:00:10

1 beep at 0:00:09; 0:00:08; 0:00:07...0:00:01

continuous beep at 0:00:00 for ten seconds

At each of these periods the display will briefly show the time left. Press MODE to return
to the heading display.

12