beautypg.com

Priority flow hydraulic systems, Non-active hydraulic system – Great Plains 3S-3000HDF Operator Manual v2 User Manual

Page 37

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

33

2014-02-11

Table of Contents

Index

195-068M

Priority Flow Hydraulic Systems

On some tractors with load-sensing hydraulics, the circuit
#1 is capable of taking nearly 100 percent of available
hydraulic flow. Operating the openers or markers on
circuit #1 will starve the other circuit, making one function
inoperable.

To operate markers and constant opener down pressure
at the same time, connect the openers to circuit #2 and
the markers to circuit #3.

Non-Active Hydraulic System

To run drill with open-center hydraulics or
fixed-displacement hydraulic pumps requires a Great
Plains kit, part number 194-143A. After installing the kit,
refer to the following instructions for opener operation.

1.

Lower opener frames by pushing forward on tractor
hydraulic lever. Lock lever temporarily in this position
while adjusting opener down pressure.

Refer to Figure 26
2.

With tractor hydraulic lever locked forward, release
lock disk

and set down-pressure with adjustment

knob

. Watch pressure gauge and dial in desired

pressure on openers. There is one pressure-control
valve for openers on center section and one for
openers on wing sections of drill.

Note: Rotate knob clockwise to increase pressure and

counterclockwise to decrease pressure.

3.

Once pressure is set, set knobs with lock disks

.

4.

After opener down pressure is set, return tractor
hydraulic lever to neutral. This locks-in the selected
pressure, and opener frames remain fixed in this
position.

Machine Damage Risk: Open-center tractors and tractors
with fixed-displacement pumps are not designed to provide a
continuous supply of pressurized oil to remote valves. Locking
hydraulic lever forward on these tractors can cause overheat-
ing of hydraulic oil and tractor damage. After setting opener
down pressure, always return hydraulic lever to neutral.

Note: On some tractors with very positive remote hydrau-

lic checks, a slight increase in the reading on the
pressure gauges may occur after tractor remote le-
ver is returned to neutral. This is caused by back
pressure on opener cylinders and should be ig-
nored. The net operating pressure on opener cylin-
ders is maintained at the pressure you selected
while tractor remote lever was held forward-not at
the apparently increased pressure. Reactivating
tractor lever forward will confirm this.

FigureSpacer

Figure 26 - Non-Active

Pressure Control Valves

26477

1

2

1

2

1

This manual is related to the following products: