Great Plains Yield-Pro 1625 Planter 2005 User Manual
Page 8

402-181M
12/12/2005
Great Plains Mfg., Inc.
2005 Field Update Kits
8
Refer to Figure 13
16. Place seed strainer grate weldment (2) in seal
holder weldment (3).
17. Peel release paper from back of meter top seal
(1). Stick seal (1) on seal holder weldment (3).
18. Measure distance from top of meter top seal
(A) to top angle on manifold (B). NOTE : See
Figure 6 on page 5. Make sure new seal (1) is
replaced at same height as old seal.
Figure 13
Top Seal
23464
Figure 12
Seal Holder Weldment
Refer to Figure 12
13. Slide previously removed corner seal mount
weldments (3) along front corners between
top of manifold (1) and seal holder weldment
(2).
14. Attach new seal holder weldment (2) to new
manifold top weldment (1) using 1/4-20 x 5/8
bolts, 1/4 flat washers, 1/4 lock washers, and
1/4-20 hex nuts.
15. Secure corner seal mount weldments (3) to
manifold top weldment (1) and seal holder
weldment (2). Use 1/4-20 x 1 bolts , 1/4 flat
washers, 1/4 lock washers, and 1/4-20 hex
nuts. Attach top corner seals to corner seal
mount weldments. NOTE: Top of corner
seals need to be 1.19" above top of main
seal.
Install Fan Inlet Rain Shield
Refer to Figure 14
1.
Attach fan inlet rain shield (1) to outside of
fan using four #12-14 x 3/4 hex head
screws (2).
NOTE: Shield should overlap intake screen
mounting plate against fan housing.
23417
Figure 14
Fan Inlet Rain Shield
23462