beautypg.com

Planter control channel setup – Great Plains YP40F Operator Manual User Manual

Page 60

background image

56

YP2425F/YP4025F

Table of Contents

Index

Great Plains Manufacturing, Inc.

403-362M

Table of Contents

Index

2013-03-25

Planter Control Channel Setup

(Controlled Hydraulic Drive)

25. At the Control Setup screen, press the Channel

Setup button

.

26. Select Channel 1 and verify that the channel is set to

Planter Control.

27. Enter desired values using Table as reference.

28. After planter control setup, calibrate hydraulic valve

by pressing the Valve Cal button

.

29. Ensure implement is raised. With brakes locked and

transmission in PARK position, start engine.

30. Engage hydraulics and run engine at normal speed

until hydraulic fluid is at operating temperature.

31. Verify point row clutches are turned ON.

Equipment Damage Risk:
Do NOT perform the next step unless meters are installed in all
locations across planter row units or drive damage may occur.

32. Press the START button

. Turn the master switch

to the ON position.

33. The valve calibration starts immediately. Keep the

hydraulics engaged until the calibration completes.

34. When the screen indicates calibration is complete,

press the Channel Setup button

to return to

Channel 1 home screen.

35. Turn the master switch OFF.

36. To set up additional control channels (planter or

fertilizer control), press the Next Channel button

.

37. Press the Work Screen button

when channel

configurations are complete to return to the Main
Work screen.

Once a control channel has been established as Planter
Control, any new materials established as Planter
Control on the Material Setup screen are automatically
added as optional materials for Planter Control channels
on the Control Setup screen.

Planter Control Setup

Default

Value or

Value to

Enter

Instructions/Definitions

Type

Planter

Control

Set desired Channel Type as
Planter Control.

Material
Name

Displays only materials that
have been configured for the
channel type.

Control
Mode

AUTO

Auto is used in normal
operating conditions
calculating the rate of how the
system is running. Manual
mode acts as an override if
application rate sensors are
inoperable allowing the use of
increase/decrease buttons to
set the fl ow rate for the
control. Refer to System
Configuration section of PDC
Operator manual for additional
information.

Drive
Type

PWM

A hydraulic valve varies the oil
flow to the motor proportioned
to the electric current supplied.

Drive
Frequen
cy

100 Hz

If not using a DICKEY-john
supplied valve, see the
manufacturer’s specifications
for drive frequency.

Input
Filter

50

Feedback frequency filter for
the control channel. DO NOT
CHANGE.

Gear
Ratio

1.900

Specifies the actual ratio from
the feedback sensor to the
seed meter shaft RPM.
Number of revolutions the
feedback sensor turns in
relation to one revolution the
seed meter turns.

Sensor
Constan
t

360

Sensor Constant establishes
the number of pulses for one
revolution of the feedback
sensor. If a DICKEY-john
application rate sensor is
used, the value should be set
to 360.0.

# of
Seed
Rows

Entry of a specific number of
seed rows for the control
channel. Row assignment is