Auto configuration, To run auto config, Row status/row width setup – Great Plains YP40F Operator Manual User Manual
Page 58: Module configuration screen, Seed sensor configuration screen

54
YP2425F/YP4025F
Great Plains Manufacturing, Inc.
403-362M
2013-03-25
Auto Configuration
(Identifies sensors connected to each module)
Auto config is performed at the factory, but may need to
be done in the field as changes are made to the system
or if options are added to the base planter.
Verify Auto Config results are correct. Check that the
correct number of rows are assigned to the correct
module and number of hopper sensors are assigned
accurately.
To Run Auto Config:
10. Press the Next Page button
until the Module
Configuration button appears.
11. Press the Module Configuration button
.
12. Press the AUTO CONFIG button
.
13. Hour glass indicates system is detecting the
presence of seed or hopper sensors connected to
each module and automatically assigning them to
the appropriate module.
14. When Auto Config completes, press the Row Assign
button
to display the Row Assignment screen to
verify correct Row # is assigned to the correct
module based on serial number.
15. Enter # of rows assigned to each module.
Row Status/Row Width Setup
16. At the Row Assignment screen, press the Row I/O
button
.
17. Begin entering desired values using Table as
reference.
18. Press the Work Screen button
when Row
Status/Row Width configurations are complete to
return to the Main Work screen.
SERIAL
NUMBER
1
MODULE
TYPE
MODULE
ADDR.
WSMB-POM
WSMB-POM
2
WSMB-18R
3
10001
10001
10002
WSMT-GY
10001
4
Module Configuration Screen
10002
10003
10001
WSMB-18R
WSMB-POM
WSMB-CFM
5
6
7
(Optional)
(Optional)
# OF
ROWS
MODULE
ADDR.
TYPE
ROW
#’s
6-11
1
WSMB-18R
2
WSMT- GY
6
5
1- 5
3
WSMB-18R
5
12-16
Seed Sensor Configuration Screen
Row Status/Row Width Setup
Default Value or
Value to Enter
Instructions/Definitio
ns
Row
Width
YP2425F-2470:
70cm or 27.56in
YP4025F-1670:
70cm or 27.56in
Enter row width distance
in inches to calculate
seed rate correctly.
YP4025F-1630
30in or 76.2cm
Auto
Update
Width
Disabled
Manually enter
implement width at
Table data entry.
On/Off
Pattern
Every Row On
On/Off Pattern indicates
specific row patterns to
be on or off. Select
pre-defined planter All
Row On pattern. For
other pre-defined planter
patterns or individual
row settings, see PDC
Operator manual.
Pop/Blo
ck
Rows
Determines which
sensors are used to