beautypg.com

Great Plains YP40F Operator Manual User Manual

Page 37

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

33

2013-03-25

Table of Contents

Index

403-362M

This table covers possible issues specific to the
YP24/YP40 DF/seeder feature.

See also the Troubleshooting section of the 401-406M or
401-571M Operator manual.

Seeding Troubleshooting

Problem

Cause

Solution

Seed Hoses Plugging

Insufficient airflow to operate both
fertilizer and seed delivery systems.

Increase fan speed (page 19).
If already at 3800 rpm, open seed-leg butterfly
valve (page 19).

Air leaks

Check:
hopper lid,
hopper base to airbox seal,
clean-out door seal and
delivery hoses.

Fan circuit running in reverse

Check and re-connect circuit hoses (see
401-406M or 401-571M Operator manual).

Fan won’t run fast enough at
maximum tractor circuit setting

Check butterfly valves. Notes that tractor must
be able to supply 18 gallons/minute at 200 psi.

Fan speed low on capable tractor.
Hydraulic fan check valve is installed
backwards

Reverse installation of check valve (see
401-406M or 401-571M Operator manual).

No Seed Flow (all rows)

Material run-out.

Re-load seed. Re-check rate setting and level
sensor function if run-out was unexpected.

Bridging in seed hopper due to
material consistency

Clean-out and replace material. See page 35.

Butterfly valve closed at seed leg

Check setting of valve. Tighten bolt.

Planting Rate Low
(single row)

Airbox outlet plugged.

Clean-out hopper (page 35).
Inspect manifold outlet area.