beautypg.com

Air release tube, Meter box door seals, Meter flutes – Great Plains YP40F Operator Manual User Manual

Page 47: Seasonal

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Maintenance

43

2013-03-25

Table of Contents

Index

403-362M

Air Release Tube

1 tube each wing end fertilizer delivery hose;
2 tubes per planter

Inspect. Clean any build-up on screen. Replace if
damaged. Re-install with opening facing down.

Note: Although depicted in exploded view, the tube is a

weldment and the screen cannot be removed.

Meter Box Door Seals

2 seals per planter

Inspect and replace if leaks are detected or appear
imminent.

Meter Flutes

1 flute shaft per planter,
2 sets of 2 stars (4 stars),
4 sets of 3 stars (12 stars);
16 stars total (each star is two halves)

Inspect from above with hopper empty. Shaft rotation is
required to expose all surfaces. Replace any broken or
visibly worn stars.

Seasonal

29723

Seasonal

31016

Seasonal

31016