beautypg.com

Coulter adjustment, Coulter height adjustment, Coulter applicator adjustment – Great Plains YP40F Operator Manual User Manual

Page 33

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Adjustments

29

2013-03-25

Table of Contents

Index

403-362M

Coulter Adjustment

The frame-mounted coulters standard on the
YP2425F-2470, YP4025F-1630 and YP4025F-1670 are
configured for “zone” application: 5cm offset from seed
furrow, and
5cm depth, or “2x2”in.

As blades wear, or under unusual field conditions, you
may need to adjust the coulter depth. If the depth is
adjusted, the applicator needs to be adjusted as well.

Coulter Height Adjustment

Refer to Figure 17
1.

Raise the planter. Install transport locks.

2.

Move the planter to a flat level surface. A paved area
is ideal.

3.

At each coulter, measure the raised tool bar height
(“Bar_Height”)

.

4.

For a 2.5cm (2in) coulter depth, compute the ideal
raised height

of the disk edge.

Metric:

Inch:

5.

Reset the coulter shank to the new “Edge_Height”.

Coulter Applicator Adjustment

Normally, the coulter tine tip

is set to exactly ground

level, although you may set it higher or lower for unusual
conditions. To change the height, loosen the mounting
bolt

and move the applicator weldment up or down.

If you are adjusting the tine height, to ground level, with
the planter raised, use:

Metric (cm):

or, U.S. customary (inches):

Figure 17

Dry Fertilizer Coulter

31109

1

2

4

3

1

2

Edge_Height

Bar_Height

66

5

=

Edge_Height

Bar_Height

26

2.5

=

3

4

Tine_Height

Edge_Height

5

+

=

Tine_Height

Edge_Height

2.5

+

=