beautypg.com

Channel setup – Great Plains YP4425A Material Rate User Manual

Page 47

background image

Great Plains Manufacturing, Inc.

Table of Contents

Volumetric Seeding

43

2014-05-13

Table of Contents

401-627B

24. Press the Control Setup

softkey.

25. Press the material labelled “SPLIT AIR”.

26. Reset the target rate to the meter pressure

suggested by the Hydraulic Rate Charts on page 46
(typically 2.0 or 2.5 inches of water pressure).

27. Press the Work Screen

softkey to return to the

main work menu.

You need a light weight container for each row sampled,
and a scale that is accurate at the expected sample
weight. Great Plains recommends using enough rows
and/or revolutions to generate a sample of about
10 pounds (4.5 kg), ideally:

• Use at least two rows.

• Use no fewer than 5 meter revolutions.

Figure 27

Channel Setup Screen

31649e

Channel Setup

Setup

Item

Value or

Default

Comments

Type

GRAN SEED

CONTROL

This means not singulated,
and monitor controls rate. This
Type must match the Type of
any material metered this way.

Material

Name

Displays a choice of GRAN
SEED CONTROL materials
from Material Library

Control

Mode

Auto

Drive Type

PWM 1

Drive

Frequency

100 Hz

Input Filter

50%

Gear Ratio

1.9

See the DICKEY-john

®

Quick

Start Guide for your planter
model and row spacing.

Sensor

Constant

360

# Seed

Rows

specific>

Use the number of active
rows.

Channel

Width

Active row spacing times
active row count

Precharge

0

For Example
4 containers each weighing:

8 oz.

8 oz

× 4 = 32 oz

ContainerWeight

at step 43 on

page 45 is:

2 lbs