Configure monitor, Material setup, Material setup: hydraulic drive – Great Plains YP4425A Material Rate User Manual
Page 34

30
YP3025A, YP4025A and YP4425A
Great Plains Manufacturing, Inc.
401-627B
2014-05-13
Configure Monitor
Note: This setup requires User Level 2 access on the
AI100 or AI120 seed monitor, which is password-
protected.
Material Setup
Refer to Figure 11
1.
Navigate to the Control Setup
and then the
Material Setup screen
.
2.
Select an available default “MATRL” to redefine as
canola, or select an existing named material to
rename.
In the example screen at right, “MATRL 9” was
selected, and “Canola” typed in at the next step.
Material Setup: Hydraulic Drive
Refer to Figure 12
3.
Touch the material name to edit it to Canola. The
population ranges and rpm limits are given by the
chart on the next page.
Figure 11
Control Setup
36070
Type
must be PLANTER CONTROL
for hydraulic drive
Preset
Target Rate
Max/Min Rates
Inc/Dec
Seeds per Rev
must be 250 for 817-991C disk
Disc Low Limit
5
Disc High Limit
25
Prod Level Alarm
Figure 12
Material Setup, Hydraulic Drive
36073