beautypg.com

Great Plains YP4425A Material Rate User Manual

Page 16

background image

12

YP3025A, YP4025A and YP4425A

Table of Contents

Great Plains Manufacturing, Inc.

401-627B

Table of Contents

2014-05-13

5.

Plant at the desired planting speed for slightly more
than the computed sample run length.

6.

Measure off the sample distance, balanced in
between where seeding started and stopped.

7.

Count the number of seeds over the distance
measured. Also note the consistency of the seed
spacing.

8.

Compute the rate for a full acre or hectare.

For a 1/1000th sample, multiply the counted seeds
by 1000.

For a 1/200th sample, multiply the counted seeds by
200.

9.

If the field and chart rates vary by more than a few
percent, re-check planter setup, including meter disk
or cell count, air system, hydraulic drive setup, chain
slack, etc. If seed spacing is irregular, this suggests
a seed delivery problem, and not a rate setup
problem.

10. While planting, pay attention to the seed monitor. In

addition to confirming the single-row furrow check, it
will also provide field rate data on all the other rows,
and alert you to any irregularities or stoppages.

USc Example:
Sample size:

1/1000th ac

Plant for approximately:

25 feet

Measure 1 row of central:

17 feet 5 inches

Metric Example:
Sample size:

1/1000th ha

Plant for approximately:

20 meters

Measure 1 row of central:

14.29 meters

USc Example:
Seeds counted:

121

Computed for full acre:

121

× 1000 = 121,000

This differs from target by:

1.8%

Metric Example:
Seeds counted:

309

Computed for full hectare:

309

× 1000 = 311,000

This differs from target by:

1.3%