Great Plains 2515P Marker Option User Manual
Page 7
3/19/2003
113-685M
Great Plains Mfg., Inc.
7
Installation Instructions
With Sequence Valve
Refer to Figure 10.
1.
Mount sequence valve (1) on bean machine
using mounting plate (2). Bolt plate to inside
end of left-hand-box panel (3) using one 1/2-
inch hex bolt (4).
2.
Bolt valve to mounting plate with two 3/8 x
3/4-inch hex bolts and lock washers (5).
3.
Install elbow fittings in cylinder ports. Discard
adaptor fitting and two needle valves provided
in marker kit.
4.
Use hoses provided to connect valve ports to
cylinders. Refer to Figure 11 for port connec-
tions.
5.
Connect your own hydraulic hoses to ports on
front of valve. Route hoses to tractor outlets.
6.
Using orange cable tie, secure plastic hose
label to hydraulic hoses near tractor outlets.
See Figure 9 on the previous page.
7.
Proceed with "Bleeding Marker Hydraulics,"
page 8.
Figure 10
Sequence Valve Assembly
18416
Figure 11
Hydraulic Hose Connections
18417