3.4 OPTIONAL AC DISCONNECT SWITCH INSTALLATION: Connect disconnect switch in
line with VAC line (black wire) (see Figure 13).
Figure 3.1
Figure 13 Figure 14
3.5 Finish power supply AC connection by connecting black VAC line to black input cord of
power supply, and white neutral to white input cord of power supply. Connect green
ground wire from line to the same metal surface the power supply is mounted on (see
Figure 14).
3.6 Power Supply Information:
Table 1
– Power Supply Information
Item
Number
Ordering Description
Power
Supply
Wattage
Input
Voltage
(VAC)
Input
Current
(A)
Output
Voltage
(V)
51514
OT75W/24V/UNV
75W
120/277
0.76/0.33
24
51522
OT96W/12V/UNV
96W
120/277
0.97/0.39
24
Table 2
– Max. Number of Modules per Power Supply
Item Number
Ordering Abbreviation
Max. Modules per
Power Supply
51514
OT75W/24V/UNV
13
51522
OT96W/12V/UNV
17
Optional
Disconnect
Switch
VAC out from
Disconnect Switch
VAC into Disconnect Switch