beautypg.com

OSRAM SYLVANIA ProPoint Industrial Linear LED Luminaire User Manual

OSRAM SYLVANIA Lighting

background image

Rev 110907-7

ProPoint™ Industrial Linear LED Luminaire manufacturers recommended installation instructions

1


Mechanical Installation

• The light engine and driver spacing to other heat producing components shall be minimum 4 inches

when minimum spacing to sidewalls and top of enclosure is kept at minimum 2 inches.

• The light engine and driver are UL Listed for indoor and outdoor applications; it can be directly

attached to the structure.

• Attach driver to structure at mounting holes indicated by arrows (Fig 1) using stainless steel

hardware.

• Attach light engine to structure at mounting holes indicated by arrows (Fig 2) using stainless steel

hardware.

• Do not over tighten.

Electrical Installation

• The driver has a single output that complies with Class 2 output requirements.
• The maximum rated output power of the driver is 96 watts, constant current.
• The [AC input] and [DC output/DC occupancy sensor control] are located at opposite ends of the

driver (Fig1).

AC input: To maintain IP66 rating a liquid tight conduit fitting must be used on the AC Input (1/2”

NPT); threaded on to driver bracket, provided for connection to the AC circuit (Fig 3).

o

Open access panel on top of driver by unscrewing 2 screws, make AC connections and re-

tighten screws on access panel using 12-15 in-lbs of torque (Fig 4).

DC output: water tight connector is provided on the output side of the driver (A, Fig 5).

o

Attach this connector to the connector provided on the light engine (install optional “Y”

connector and/or extension cable in between driver and light engine, if necessary). Ensure
that connections are securely tightened to prevent water from entering (Fig 6).

• Bi-level Dimming using a DC Occupancy Sensor Control

o

Enable Dimming Control

1. Cap the red wire.
2. Cap the black wire.
3. Connect the violet (+sense) and gray (-sense) wires to the occupancy sensor

o

Disable Dimming Control

1. Connect the red and black wires 2. Cap the violet wire 3. Cap the gray wires

Box Contents:

• Luminaire, 1 or 2 in kit
• UL Listed LED Light engine (1 or 2 in

Kit)

• UL Listed LED Driver (1)
• “Y” connector cable (in Kit)
• 10 ft extension cables (2 in Kit)

Optional Accessories

• Y-Cable

• Pig-tail

• Extension Cable

Model Numbers:

74851: IL-L-50-745-LB-MV-24-GR

74852: IL-L-100-745-LB-MV-48-GR

74854: IL-L-100-745-LB-MV-24-GR /K