OSRAM SYLVANIA ProPoint Outdoor Luminaire Post Top 1 User Manual
Propoint, Outdoor luminaire post top 1
ProPoint
TM
Outdoor Luminaire Post Top 1
Installation Guide
Read all instructions carefully before attempting
installation. If you do not understand these
instructions, please consult your local distributor.
Thoroughly inspect the luminaire for any freight
damage. Freight damage should be reported to the
delivery carrier.
Compare the catalog/model number description on
the packing slip with the fixture label to assure that
you have received the correct product.
Disconnect power during installation and before
servicing.
Product is for outdoor installation and use only.
To avoid risk of fire or shock, this fixture must be
wired in accordance with the National Electric Code
and applicable local codes or ordinances.
All work should be performed by a qualified
electrician.
To ensure personal safety, proper grounding is
required.
Cut off top lantern. Dark sky compliant,
top mounted horizontal LED assembly.
Horizontal flat tempered glass (no
external vertical glass surfaces)
www.sylvania.com
Safety Warnings:
Luminaire Installation:
Verify power is off prior to wiring luminaire
Connect neutral, hot, and ground wires from luminaire to wiring
pole (black, white, & green wires). Loosen (8) set screws on filter.
Slide luminaire over ø3
” O.D. x3”H Tenon\pole. (Use caution not to
slice or fray wiring when sliding luminaire over Tenon.
Tighten all 8 set screws. Power up luminaire.
Quick release butterfly hinge
Loosen set screw (8 @ 90 degrees)
Fitter to receive ø3
”O.D.x3”H. Tenon
Connect wiring using quick disconnects
connectors
ø3
”O.D.x3”H
Tenon
Tighten set screw
(8 @ 90 degrees)
Wire way concealed
in arm
Grounding nut
Quick disconnect
terminal block
Cast aluminum heat
sink
Intelligent power
supply (driver)
Quick release
butterfly hinge
LED188