OSRAM SYLVANIA ProPoint Outdoor Luminaire Small Light Pack User Manual
Propoint, Outdoor luminaire small light pack (slp)
ProPoint
TM
Outdoor Luminaire Small Light Pack (SLP)
Installation Guide
Read all instructions carefully before attempting
installation. If you do not understand these
instructions, please consult your local distributor.
Thoroughly inspect the luminaire for any freight
damage. Freight damage should be reported to the
delivery carrier.
Compare the catalog/model number description on
the packing slip with the fixture label to assure that
you have received the correct product.
Suitable for mounting withing 1/2M (4 ft) off the
ground.
No user serviceable parts inside. Contact
manufacturer for LED replacement.
Suitable for wet locations.
Disconnect power during installation and before
servicing.
Caution. RISK OF FIRE . This product must be installed
in accordance with the application installation code by
a person familiar with the construction and operation
of the product and the hazards involved (marking
provided on carton).
To ensure personal safety, proper grounding is
required.
Small Light Pack luminaire is available
in 15 and 30 watts with Type V
distribution
www.sylvania.com
Safety Warnings:
Luminaire Installation:
Center the luminaire mounting plate over the junction box and attach using
mounting hardware. Pull supply wires through center hole of mounting plate.
Latch the Small Wallpack fixture onto bracket as illustrated.
Use supplied wire nuts to connect LED driver input leads to
supply leads (refer to wiring diagram on page 2). Push wire
and wire nuts up through hole in mounting plate and into
junction box.
Hinge fixture up to closed position and secure using large fixture
securing screw provided. Tighten to 40-50 in-lbs.
LED179
Securing screw
Fixture lens
Integrated hook/hinge
Luminaire wire
exit
Universal mounting
plate
Universal mounting plate
Mounting hardware
(not included)