APPENDIX A – FAULT CODES

CODE

STATUS

DESCRIPTION

F01

N

Over discharged battery (<1.90vpc after 30 seconds of charge)

F02

N

Deep discharged battery (<1.90vpc after 30 seconds of charge > 1.90vpc)

F03

N Sulphated

battery

F04

S Charger

over

heating

F05

S

Mains failed during charge

F06

R

No output current

F07

C

Incorrect battery < 1.70

F07 (+Y led on)

C

Incorrect battery > 2.25

F09

C

Bulk charge time-out

F10

C

Second stage time-out (Profile Dependant)

F11

C

Incorrect Mains Frequency

F12

C

Control hardware (MCU)

F13

S Thermistor

fault

F16

S

Battery overheating (if temp probe fitted)

F17

C

Auto balance charge time-out

F18

C

Battery disconnected without pausing charge

F19

C

Battery disconnected in cool down period

Key: -
C
= critical fault

Ö

charge stopped

Ö

fault code displayed permanently

S = suspend fault

Ö

charge suspended until criteria fulfilled

Ö

fault code displayed permanently

R = retry fault

Ö

charge retries after 20 seconds

Ö

fault code display alternating with standard

display

N = non-critical fault

Ö

charge continues

Ö

fault code display alternating with standard display