design of the system in which the pump is to be installed. Consult Johnson Pump
(UK) Ltd or your local distributor for assistance.
Pressure
Rating
Displacement
Maximum
Speed
Port Size
Maximum
Temperature
Maximum
Viscosity
bar
psi
L/rev US gal /
rev
Rotor rpm
mm
inches
°
C
°
F
cPs
ssu
12
174
0.02 0.00528
1750
12 & 19 ½” & ¾” 150
300
150,000 682,500
If the system or product characteristics are to be changed from the original
application for which the pump was selected, the factory or their authorized
distributor should be consulted to ensure the pump is suitable for the new
application.
The pump should not be subjected to sudden temperature changes to avoid the risk
of damage from sudden expansion/contraction of components. Care should be taken
when selecting pumps for handling liquids containing abrasive particles as these may
cause wear of pump head components. Contact the factory or their authorized
distributor for advice or assistance.
Model Designation: AL05
Standard Construction:
•
316L St. Steel Wetted Parts (0.6
µ
M Surface Finish).
•
Multi-Lobe (5 Lobe) Rotors
•
1/8” Male BSP Flush Connections
•
¾” Tri-Clamp Connections
•
Foot Mounted
•
FDA EPDM Elastomers
•
Silicon Carbide Seal Faces
•
Sealed For Life Grease Lubrication
Should any additional information be required, contact the factory or their authorized
distributor quoting the pump model and serial number as stated on the nameplate
fastened to the exterior of the pump.
Should this be damaged or missing, the serial number is also stamped on the
gearbox endplate.