Installation of peek® bushings, Danger – Viking Pump TSM270: RL41507 Industrial Rotary Lobe User Manual
Page 9

SECTION TSM
270
ISSUE
F
PAGE 9 OF 10
When installing the bushings, extreme care must be taken
to prevent breaking. The additional precautions listed below
must be followed for proper installation:
• A press must be used for installation.
• Use Loctite® #4203 or #411 on the outside of the bushing
to hold the bushing in the housing.
• Be certain that the bushing is straight. The groove in the
bushing should line up with the groove in the casing.
• Do not stop the pressing operation until the bushing is in
the proper position; starting and stopping may result in a
cracked bushing.
• Check the bushing for damage after installation.
INSTALLATION OF PEEK® BUSHINGS
PEEK
®
is a trademark of Victrex PLC
Loctite® is a trademark of Henkel Consumer Adhesives, Inc.
DANGER!
Before starting pump, be sure all drive equipment
guards are in place.
Failure to properly mount guards may result in seri-
ous injury or death.
DANGER!
Failure to Follw the above listed precautionary
measures may result in serious injury or death.