40 or 50 amp PCB Removal and Installation

1. Remove the four screws (one in each corner) of the smaller 40 or 50 amp PCB to the right of the Main PCB.

Set

the screws aside for reattachment later.

Main PCB

4 Mounting

screws

Art # A-09394

2. Following proper static discharge precautions, locate the new 40 or 50 amp PCB and install in the same orienta-

tion as the one removed. Torque screws to

16-18 in. Lbs. Do not over tighten.

Capacitor PCB Installation

Following proper static discharge precautions

1. Position the power supply on its side so the main PCB’s are in a relatively flat orientation. This is to help keep

the Insulating sheet in place until the Capacitor PCB can be attached.

2. Locate the Insulating sheet included in the kit. This is a thin paper like or plastic type material with a number

of holes and slots. Position it on the 40 or 50 amp PCB with all mounting standoffs showing through the holes

and slots. See illustration below.

Check all holes

and slots for

clearance

Art # A-09392